Model SHS-PFT-30
A portable trolley that filters new oil before it goes into a machine and cleans oil already in service — 28 lpm through a 10 µm spin-on element, run by one person from any 415 V plant socket.
What it does
Oil delivered in a drum is typically no cleaner than ISO 20/18/15 — worse than most pumps and valves in a normal hydraulic system will tolerate. Contamination is picked up during blending, handling, storage and decanting. The PFT-30 lets one person filter that oil into the reservoir instead of pouring it in, and clean the oil already in a machine without draining it.
A gear pump draws oil through a Y-type strainer and delivers it through a spin-on filter element. A check valve across the filter opens if the element blocks, protecting both the element and the pump.
Typical uses
Specification
| Delivered flow | 28 lpm at 1440 rpm, measured at 5 bar |
|---|---|
| Working pressure | 2 to 5 bar |
| Maximum system rating | 10 bar (set by the hose assemblies) |
| Filtration | Spin-on element, 10 µm (25 µm available to order) |
| Filter bypass | Check valve, 5 bar cracking pressure |
| Suction strainer | Y-type, 149 µm, 1" BSP, cleanable |
| Pump | External gear, 21 cc/rev |
| Electric motor | 0.55 kW, 4-pole, TEFC, class F, B35, frame 80 |
| Electrical supply | 415 V ±10%, 3-phase, 50 Hz; DOL starter with thermal overload |
| Supply cable | 20 m, 4-core 1.5 sq mm, with 4-pin 20 A plug |
| Suction hose | 5 m, 1" ID, PVC with helical spring, swivel nuts |
| Delivery hose | 10 m, ¾" ID, PVC with helical spring, swivel nuts |
| Fluids | Mineral hydraulic, gear, lube and turbine oils |
| Fluid temperature | −10 °C to +60 °C |
| Viscosity at start-up | 150 cSt maximum |
| Seals | Nitrile standard, fluorocarbon to order |
| Construction | Fabricated steel frame & drip tray, two-pack epoxy paint |
| Dimensions (H × W × D) | 1000 × 560 × 480 mm (nominal, hoses stowed) |
| Dry weight | 52 kg (without oil) |
The model designation refers to the nominal frame and pump size, not to delivered flow. Ratings are not duties — the unit works at 2 to 5 bar; the 10 bar figure is the rating of the machine as supplied, set by the PVC hoses.
Why this build
Changed by hand in under a minute — no tools, no open housing, no spillage. Shorter maintenance stops.
Flow bypasses a blocked element at 5 bar instead of collapsing it, so the element can't rupture and shed debris into clean oil.
Coarse debris is stopped before it reaches the pump — longer pump life, fewer breakdowns.
Element condition is read at a glance while the unit runs, so elements are changed when actually blocked, not on a guess.
Tips and moves like a sack barrow on 10-inch wheels — one-person operation, no lifting tackle.
Reaches a drum on the floor and a reservoir across the bay; the unit stays put while the operator works both ends.
Performance
Component makers set a cleanliness level for their products. Compare it with the oil you are actually putting in — new drum oil is typically ISO 20/18/15.
| Component | ISO 4406 |
|---|---|
| Servo valves | 16/14/11 |
| Proportional valves | 17/15/12 |
| Piston & vane pumps | 18/16/13 |
| Directional & pressure valves | 18/16/13 |
| Gear pumps & motors | 19/17/14 |
| Cylinders & flow controls | 20/18/15 |
| New oil, as delivered in the drum | 20/18/15 |
| Reservoir | One pass | Seven passes |
|---|---|---|
| 200 litre | 7 min | 50 min |
| 400 litre | 14 min | 1 h 40 min |
| 800 litre | 29 min | 3 h 20 min |
Seven passes is the usual figure for a noticeable improvement. A 10 µm element typically improves cleanliness by three to four ISO codes over repeated passes — enough to bring new drum oil into range for gear, piston and vane pumps, directional and pressure valves and cylinders. Servo/proportional systems need finer, two-stage filtration.
How to order
Select one symbol from each box. Example: PFT30-10Q-N-S — 28 lpm trolley, 10 µm element, nitrile seals, standard hose set.
| Model | PFT30 — 28 lpm |
|---|---|
| Element | 10Q — 10 µm · 25Q — 25 µm |
| Seal | N — nitrile · V — fluorocarbon |
| Hose set | S — 5 m suction, 10 m delivery · X — special |
Every unit is built for 415 V, 3 phase, 50 Hz. Marine, four-wheel and other special executions are engineered to order.
Replacement elements & consumables
| Part number | Description |
|---|---|
| SHS-E-10Q | Spin-on element, 10 µm |
| SHS-E-25Q | Spin-on element, 25 µm |
| SHS-S-149 | Strainer screen, 149 µm |
| SHS-H-S5 | Suction hose set, 5 m, with wand |
| SHS-H-D10 | Delivery hose set, 10 m, with wand |
| SHS-K-SEAL | Seal kit |
Quote the full unit model code when ordering elements. Each unit is tested before despatch (flow, pressure hold & leak, bypass cracking pressure, insulation & earth continuity, two-hour run) and ships with a works test certificate and guarantee.
Questions
10 µm spin-on element as standard, 25 µm to order. A 10 µm element typically improves oil cleanliness by three to four ISO 4406 codes over repeated passes.
At 28 lpm, one pass of a 200 litre reservoir is about 7 minutes and seven passes about 50 minutes; a 400 litre reservoir is about 14 minutes per pass. Seven passes is the usual working figure.
Yes — that's a primary use. New drum oil is typically ISO 20/18/15, dirtier than most components tolerate. Filter it into the reservoir rather than pouring it in.
415 V, 3-phase, 50 Hz with a DOL starter, 20 m cable and a 4-pin plug — it runs from a normal plant socket, no transformer.
Those need finer, two-stage filtration. For that duty — and for flushing new pipework — see our flushing trolley range.
Keep your oil clean